Automated transdermal testing
Automated Transdermal Sampling SystemThe Logan System 912-SCT-S is designed to save valuable time bydelivering precise transdermal samples into HPLC vials automatically.The SYP Series Syringe Pump module withdraws and measures samplevolumes from transdermal diffusion cells at each time interval.Individual samples are dispensed simultaneously into HPLC vials thatare stored in the SCT Series Sample Collectors. The replacement mediatakes place right after each sampling. The lift plate tilts the Franzcells to allow all the air bubbles to purge out of the cells. This willinsure that there are no air bubbles under the skin/patches!All modules are controlled by a stand alone system controller or software program via IBM- compatible PC. During the test: The stir bar does the mixing. No circulation takes place during the test. For Sampling: Syringe pump takes samples from Franz cells a few minutesbefore the sampling time to pre- condition the syringes and then takessample at the time interval. The system wastes .5 ml to wash the sampledelivery lines and then delivers samples into HPLC vials. Syringeswithdraw all remaining samples from the delivery lines‚ where they getsent back to the cells. For media replacement: Franz cell support tilts‚ and the syringes takereplacement media and then re-fills the Franz cells. All bubbles arepushed out to waste‚ patented Tilted Cell design. Specification:FDC-6 Transdermal Diffusion Cell Drive Console Power requirements :110V - 120V 50/60 Hz or 220V - 240V 50/60 Hz Drive Positions: 6 Cell Positions : 6 Control Zone : 2 Zone 1: Drive Positions 1 2 3 Zone 2: Drive Positions 4 5 6 Stirring Method : Teflon coated magnetic bar Speed : 300 RPM Heater : 700 watts Temperature range: 25_45 ° C Temperature accuracy : . ± .1 ° C Syringe Pump Syringe Pump position: Up to 6 Syringes Syringe Pump Driver: By high torque motor with encoder Control: Manual or PC Control Syringe size: 5 ml (others available) Voltage: 110 & 220V 50/60Hz Flow rate: Adjustable or Fixed at approx: 1 ml per minute with 10 ml syringe Accuracy: + / _ 1% depends on the calibration & stroke of the syringe Sample collector:Delivery position: up to 6 positions Sample rack: Up to 8 X 20 total 160 sample vials Waste position (HOME): One position on left. Standard vial size: For Waters / Agilent / Shimadzu Voltage: 24 Volt DC from 110 & 220V 50/60Hz Power supply Sample time points: Up to 20 time points Volume accuracy: Within 1% of the collection volume |
We currently have demo equipment available for the Refractometers, Density Meter, Smartchem and SPE Autosampler.
18/11/2008
DDM 2911 Density Meter is available for demonstration
We are pleased to announce that Steroglass STRIKE 300 Rotary Evaporator won the GOLD AWARD as the most innovative and well designed instrument in the world according the IBO magazine. They declare that "The Strike 300's innovative industrial design clearly distinguishes it by creating an appealing visual appearance and enhanced end-user experience."
Phone: 02 9543 7377
Mobile: 0418 489 842
Fax: 02 9543 7366
Email: sales@alpe.net.au
Service NSW 0402 473 740
Service QLD 07 5465 6306
Service SA 0419 800 918
Service Vic 0408 305 325