Phone: 02 9543 7377
                                                       Mobile: 0418 489 842
                                                       Fax: 02 9543 7366
                                                       Email: sales@alpe.net.au
                                                                        

 
 
This catalog has no sub-catalogs.

Automatic Cleveland Open Cup Flash Point Tester

Automatic Cleveland Open Cup Flash Point Tester


Test Method

• Flash point operation between ambient and 400°C

• Gas or electric ignition

Features and Benefits

• Conforms to ASTM D92 and related specifications

• Simple automation routine for easy operation

• For flash points above 79°C (175°F)



--------------------------------------------------------------------------------

Automatic Cleveland Open Cup Flash Point Tester

The automated Cleveland Open Cup flash point tester accurately determines flash and fire point temperatures of viscous petroleum products including oils and bitumens over an extended temperature range. When examining highly viscous specimens‚ a preheating time and temperature are set in order to liquefy the sample for testing. The surface skin from bituminous samples can be removed with a skimmer. The flash/fire point tests are simply conducted by mounting the flash cup filled with sample into the test position and selecting a pre-programmed test method or the search mode to determine an approximate flash point. The test results are automatically corrected to standard pressure (101.3 kPa). Equipped with a differential Pt-100 RTD probe‚ the system is designed to duplicate the response time of a mercury-in-glass thermometer. Multiple sensors continually monitor instrument function‚ displaying an error message if a problem is detected. The performance of the ionization sensor which detects the flash and fire points is continuously monitored‚ and the user is notified upon the need of replacement. If a flash is not detected 20°C above the expected flash point or at 420°C‚ then the test is automatically aborted for safety. The system is easily interfaced with an external PC for operation and method updates. When performing a test‚ the system will display the stirring speed‚ temperature curve (also printed out)‚ and current test status. The system alerts the user if the first application of the ignitor results in a flash or if no flash point is detected at the end of the test program. If a flash is not detected 30°C above the expected flash point or at 400°C‚ then the test is automatically aborted for safety.

Specifications

Conforms to the specifications of:
ASTM D92; IP 36; ISO 2592

Electrical Requirements

115/230V 60/50Hz 1000W‚ Single Phase


Dimensions lxwxh‚in.(cm)
21x10.5x19.75 (53.5x26x50)
Net Weight:
44 lbs (20kg)

 

Special Offer

We currently have demo equipment available for the Refractometers, Density Meter, Smartchem and SPE Autosampler.

What's New

18/11/2008

  DDM 2911 Density Meter is available for demonstration

We are pleased to announce that Steroglass STRIKE 300 Rotary Evaporator won the GOLD AWARD as the most innovative and well designed instrument in the world according the IBO magazine. They declare that "The Strike 300's innovative industrial design clearly distinguishes it by creating an appealing visual appearance and enhanced end-user experience."

 

Phone: 02 9543 7377
Mobile: 0418 489 842
Fax: 02 9543 7366
Email: sales@alpe.net.au

Service NSW 0402 473 740
Service QLD 07 5465 6306
Service SA    0419 800 918
Service Vic     0408 305 325